GOLDEN RESIN

001×7H FC

Resins for Multi-Bed & Float-Bed Systems

Home › Product Center › Resins for Multi-Bed & Float-Bed Systems › 001×7H FC
001×7H FC

001×7H FC

001×7H FC is a gel-type strong acid cation exchange resin on a polystyrene-divinylbenzene matrix, bearing sulfonic acid groups (–SO₃H) — the solid equivalent of sulfuric acid. Supplied in H+ form and designed for float-bed (FC) systems; mainly used in water treatment.

Inquire Now Tel: +86 15612044421

Product Introduction

001×7H FC is a gel-type strong acid cation exchange resin on a polystyrene-divinylbenzene matrix, bearing sulfonic acid groups (–SO₃H) — the solid equivalent of sulfuric acid. Supplied in H+ form and designed for float-bed (FC) systems; mainly used in water treatment.

Typical Physical & Chemical Properties

AppearancePale yellow translucent beads
Functional group-SO3H
Shipped formH+
Total exchange capacity≥5.0mmol/g
Volumetric exchange capacity≥1.75mmol/ml
Moisture content51%~56%
True density (wet)1.17~1.22g/ml
Bulk density (wet)0.73~0.83g/ml
Particle size range0.45~1.25mm
Effective particle size≥0.5mm
Uniformity coefficient≤1.6
Osmotic-attrition whole bead rate≥60%
Max. operating temperature100 °C
Resin bed height1~3m
Service flow rate2~10BV/h
Backwash flow rate4~10BV/h
Regeneration (elution) flow rate1~2BV/h
Regenerant dosage2 BV 3~5% HCl, 2 BV 2~4% NaOH

Applications

  • Water softening
  • Pure water production
  • Hydrometallurgy
  • Rare element separation

Handling, Storage & Loading Notes

  1. Transport & storage. Store the resin in its wet state, preferably above 0 °C. For long idle periods, keep the container closed or add brine of ≥5% NaCl. Protect from freezing during transport, and do not stack heavy objects on top of the resin to avoid crushing the beads.
  2. Pre-treatment. For general requirements, one alkaline → water → acid → water cycle is sufficient; for strict requirements, perform three cycles and finish with the required ionic form.
  3. Loading. Allow for the swelling on form conversion and leave enough freeboard to prevent overflow while keeping a proper liquid level. Keep the column aspect ratio in a reasonable range to avoid channeling. Load wet or backwash to remove air bubbles from the bed.
  4. Feed quality. Before entering the resin column, the liquid should be coagulated, filtered or sand-filtered to ensure it is free of suspended solids that could clog the resin pores.
  5. Idle columns. Resin left idle in a column for a long time must be washed out and stored clean, or kept submerged in brine; it must never dehydrate. Backwash from time to time to loosen the bed and prevent caking.
Chat with Kevin